Chloride® CP70i DC/AC Inverter
Battery Monitoring System (BMS) - ATEX/IECEx
Innovative SMC/Salt Batteries & UPS Integration
Battery Monitoring System (BMS) - ATEX/IECEx
Single Cell MC/MB NiCad battery
Single Cell LCE / LB NiCad battery
Single Cell HC/ HB NiCad Battery
CleverWatch™ advanced NiCad battery remote monitoring solution
UPS Adapter CS141 Professional
UPS Adapter CS141 Budget / Budget LC
UPS Adapter CS141 HW161 Update
BAS - Battery Analyse System (On Demand)
For Manufacturers: SMARTBATTERY
EDPN IBAD-2612-ED Intelligent Battery Charge & Discharge Unit
EDPN 110LB120-T Battery Capacity Tester
EDPN 220LB300-T Battery Capacity Tester
EDPN 220LB150-K Battery Capacity Tester
EDPN 110LB300-K Battery Capacity Tester
EDPN 48LB150-K Battery Capacity Tester
Industrial UPS system offering a full-IGBT innovative design. A wide range of possible options
AC IEC
5 to 250 kVA
Full IGBT
Availability |
|
Maintainability | The easiest on the market with total components front access |
Reliability |
Innovative internal temperature reduction, through dual redundant cooling channels Multiplied redundancy with Chloride® Patented Smart Parallel Switching function that dynamically controls paralleled systems |
Key advantages |
|
User friendly |
Large color touch screen with 2000-event exportable log One of the best on the Industrial UPS Market |
USB access |
Export of all the recorded events using USB flash drive. Memorization of complete electronic settings for future maintenance needs |
Batteries compatibility |
Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries) Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion |
Low THDi |
6 – or 12-pulse thyristor rectifier Down to 5% THDI in 12-pulse SCR system with harmonic filters |
Life time |
Designed for 20+ years of continuous operation with appropriate maintenance plan |
Input |
|
Input voltage |
1-ph x 230 Vac (220, 240) 3-ph+N x 400 Vac (380, 415) ± 10 % (other voltages and tolerances on request) |
Inrush current |
≤ 1 In (without input transformer) ≤ 8 In (with input transformer) |
Power factor |
Up to 0.98 |
Frequency range |
50 Hz (60 Hz factory setting) ± 5 % |
Embedded input features |
AC input isolator switch Surge protection with MOV lightning arrestors |
Output |
|
110 Vdc |
5 – 10 – 20 (1 or 3 ph) |
220 Vdc |
10…60 (1 or 3 ph) |
400 Vdc |
40…250 (3ph only) |
Intermediate DC Circuit |
|
Nominal DC Voltage |
110 / 220 / 400 Vdc |
Voltage stability in steady state |
≤ 1 % in float mode (input within tolerance) |
Voltage ripple |
≤ 1 % RMS (with and without battery connected) |
Current limitation |
I nominal |
Charging characteristic |
IU according to DIN 41773 |
Output |
|
AC voltage |
1-ph: 230 Vac (208, 220, 240) ; 110 Vac (115, 120, 127) 3-ph: 400 Vac (380, 415) ; 208 Vac (190, 200, 220) |
Frequency stability |
With internal oscillator ± 0.1 % With reserve synchronism ± 1 % (1 to 4 % adjustable) |
Voltage stability(0-100% load variation) |
Static ± 1 %Dynamic VFI SS 111 as per IEC62040-3, class 1 |
Overload inverter(in % of nominal power) |
150 %/1 min – 125 %/10 min at nominal output voltage |
Short-circuit clearance(in % of nominal current) |
1-ph and 3-ph: 250 %/100 ms – 150 %/5 s |
Voltage distorsion |
With 100 % linear load < 2 % With 100 % non linear load < 5 % as per IEC62040-3 |
Allowable power factor |
0.5 lagging to 0.5 leading |
Allowable crest factor |
3/1 |
Embedded output features |
• Output switch • Output isolation transformer class H |
Reserve line |
|
Embedded reserve line features |
Integrated manual bypass switch |
|
Inbuilt input reserve line switch |
Battery |
|
Type |
Lead acid or nickel cadmium, vented or recombination |
Battery current limitation |
0.1 C (Lead Acid) / 0.2 C (Nickel Cadmium) |
Embedded battery features |
Inbuilt battery circuit breaker with aux. contact Battery reverse polarity protection and indication Battery Low Voltage Disconnection (LVD) Battery test, automatic or manual mode Battery room temperature sensor for battery charge compensation |
General Data |
|
Efficiency |
Up to 92 % (according to rating and config.) |
Operating temperature |
From 0 to 40 °C (without system derating) |
Storage temperature |
-20 to +70 °C |
Relative humidity |
< 95 % non condensing at 20 °C |
Operating altitude |
1000 m (without system derating) |
Cooling |
Fan assisted |
Noise (at 1m in front of the unit) |
62 to 72 dB (according to rating) |
External protection |
External IP42 |
Internal protection |
Internal IP20 |
Input/output isolation |
2500 VAC / 1 minute |
Feet |
100 mm height with feet cover |
Gland plate |
Aluminum non-magnetic, 3 mm thickness |
Dimensions & color |
From 1 x 800 mm to 2 x 1200 mm width / RAL 7035 |
Embedded system features |
Internal cabinet lighting / Lifting Eyes Auxiliary power socket Display language: EN, FR, SP, RU, TR (factory setting) |
Options
|
|
Rectifier |
Input isolation transformer Special 1-ph or 3-ph input voltage (up to 3 x 690 Vac) Input voltage tolerance from – 20 % to + 15 % Input circuit breaker with aux. contact and breaking capacity up to 70 kA Automatic reverse phase sequence correction Automatic input phase failure adaptation |
Battery |
Protection box (circuit breaker), black start, automatic or manual mode ; DC earth fault detection |
Output
|
Circuit breaker with aux. contact Emergency Power Off |
Reserve
|
Circuit breaker with aux contact
Reserve isolation transformer (H class) Reserve voltage stabilizer (servo-controlled) Stabilizer output isolator |
System
|
Parallel configuration (distributed parallel) Operating temperature up to 50 °C with derating Operating altitude up to 3000 m with derating Redundant monitored fans G3 conformal coating on elec. cards against dust, humidity / Halogen free cabling Space heater with thermostat or hygrostat |
Mechanical
|
Top cable entry – Antivibration pads Special frame color (RAL paint standards) Special feet height 200 mm or base frame |
Communication
|
Additional volt-free contacts (up to 20 relays)
Modbus RTU (RS232 or RS485) ; TCP-IP / Profibus / SNMP PPVIS monitoring software |
Standards |
|
IEC/EN 62040-1: 2008 |
Uninterruptible power systems (ups) – Part 1: Safety requirements |
IEC/EN 62040-2: 2006 |
Uninterruptible power systems (UPS) -Part 2: Electromagnetic compatibility (EMC) requirements |
IEC/EN 62040-3: 2011 |
Uninterruptible power systems (UPS) – Part 3: Method of specifying the performance and test requirements |
IEC/EN 60950-1: 2013 AMD2: 2014 |
|
Copyright © 2023 EDPN Services & System Co., Ltd by A&B Viet Nam. All Rights Reserved.