Chloride® CP70i DC/AC Inverter
Battery Monitoring System (BMS) - ATEX/IECEx
Innovative SMC/Salt Batteries & UPS Integration
Battery Monitoring System (BMS) - ATEX/IECEx
Single Cell MC/MB NiCad battery
Single Cell LCE / LB NiCad battery
Single Cell HC/ HB NiCad Battery
CleverWatch™ advanced NiCad battery remote monitoring solution
UPS Adapter CS141 Professional
UPS Adapter CS141 Budget / Budget LC
UPS Adapter CS141 HW161 Update
BAS - Battery Analyse System (On Demand)
For Manufacturers: SMARTBATTERY
EDPN IBAD-2612-ED Intelligent Battery Charge & Discharge Unit
EDPN 110LB120-T Battery Capacity Tester
EDPN 220LB300-T Battery Capacity Tester
EDPN 220LB150-K Battery Capacity Tester
EDPN 110LB300-K Battery Capacity Tester
EDPN 48LB150-K Battery Capacity Tester
CP as Customized Product. The most advanced product in terms of possibilities. A natural cooled product.
DC UPS / Natural cooling
24 ÷ 220 Vdc | 25 ÷ 2000A
SCR
Key advantages |
|
User friendly |
Large color touch screen with 2000-event exportable log One of the best on the Industrial UPS Market |
USB access |
Export of all the recorded events using USB flash drive. Memorization of complete electronic settings for future maintenance needs |
Batteries compatibility |
Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries) Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion |
Life time |
Designed for 20+ years of continuous operation with appropriate maintenance plan |
Inrush current |
Reduced ≤ 10xIn to avoid oversizing upstream protection and 2-step strat-up |
Input |
|
AC voltage |
Single phase: 1 x 230 V (220, 240) Three phase: 3 x 400 V (380, 415) |
Voltage tolerance | +/- 10 % |
Neutral configuration | Any configuration, with or without neutral |
Frequency |
50 Hz (60 Hz) |
Frequency tolerance |
+/- 5 % |
Frequency range (temporary) | 45 Hz to 65 Hz (with 50 Hz nominal) |
Total harmonic current distorsion (THDI) |
< 34 % (6-pulse version)/ < 10 % (12-pulse version)/ < 5 % (12-pulse version + harmonic filter option) |
Inrush current |
< 10 x In (for 6-pulse and 12-pulse)< 5 x In (for 12-pulse + harmonic filter option) |
Output |
|
Nominal DC voltage |
24 V ; 48 V ; 110-127 V ; 220-240 V ; 400 V |
Output DC voltage range |
17-40 V ; 36-75 V ; 88-160 V ; 176-300 V ; 296-550 V |
Voltage stability (in stabilized floating mode, input within tolerance) |
Unitary system +/-1 % |
Voltage stability (in stabilized floating mode, input within tolerance) |
Parallel systems +/-1 % to +/-2 % |
Voltage ripple |
≤ 1 % RMS, in float mode, battery disconnected |
Current limitation |
I nominal |
Battery |
|
Type |
Salt Metal Chloride, Lead acid or nickel cadmium, vented or recombination |
Autonomy |
From few minutes to several hours, on request |
Battery current limitation (typical, float, & boost modes) |
0.1 C (lead-acid battery) / 0.2 C (nickel-cadmium battery) |
General Data |
|
Operating temperature |
0 to 40 °C (-20°…55°C on request) |
Storage temperature |
-20 to +70°C |
Relative humidity |
< 95% non condensing |
Operating altitude |
1000m max without derating (other available on request) |
Cooling |
Forced ventilation |
Efficiency |
Up to 96 % according to rating |
External protection |
IP 20 according to IEC 60529 (other available on request) |
Internal protection |
Protection against unintentional direct contacts, as per IEC 60950-1 |
Noise (at 1m in front of the unit) |
60-72 dB according to rating |
Cabinet colour |
Grey RAL 7032 (other available on request) |
Dimensions |
Varying according to ratings and options |
Ratings |
|
Single phase input: |
Output voltage (Vdc): 24 Vdc … 127 Vdc Output current (A): 25…250 |
Three phase input: |
Output voltage (Vdc): 24 Vdc … 400 Vdc Output current (A): 25…2500 |