Chloride® CP70i DC/AC Inverter
Battery Monitoring System (BMS) - ATEX/IECEx
Innovative SMC/Salt Batteries & UPS Integration
Battery Monitoring System (BMS) - ATEX/IECEx
Single Cell MC/MB NiCad battery
Single Cell LCE / LB NiCad battery
Single Cell HC/ HB NiCad Battery
CleverWatch™ advanced NiCad battery remote monitoring solution
UPS Adapter CS141 Professional
UPS Adapter CS141 Budget / Budget LC
UPS Adapter CS141 HW161 Update
BAS - Battery Analyse System (On Demand)
For Manufacturers: SMARTBATTERY
EDPN IBAD-2612-ED Intelligent Battery Charge & Discharge Unit
EDPN 110LB120-T Battery Capacity Tester
EDPN 220LB300-T Battery Capacity Tester
EDPN 220LB150-K Battery Capacity Tester
EDPN 110LB300-K Battery Capacity Tester
EDPN 48LB150-K Battery Capacity Tester
CP as Customized Product. The most advanced product in terms of possibilities.
DC/AC IEC/UL
IGBT
Availability |
|
Maintainability | The easiest on the market with total components front access |
Reliability |
Innovative internal temperature reduction, through dual redundant cooling channels Multiplied redundancy with Chloride® Patented Smart Parallel Switching function that dynamically controls paralleled systems |
Key advantages |
|
User friendly |
Large color touch screen with 2000-event exportable log One of the best on the Industrial UPS Market |
USB access |
Export of all the recorded events using USB flash drive. Memorization of complete electronic settings for future maintenance needs |
Batteries compatibility |
Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries) Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion |
Life time |
Designed for 20+ years of continuous operation with appropriate maintenance plan |
Input |
|
DC voltage |
110-120 V | 220-240 V | 400 V |
Input voltage range |
88-156 V | 176-305 V | 296-507 V |
Output |
|
AC voltage Single-phase |
1 x 230 V (220, 240) | 1 x 110 V (115, 120) |
AC voltage Three-phase |
3 x 400 V (380, 415) | 3 x 220 V (200, 208, 230) |
Frequency |
50 Hz (60 Hz) |
Frequency stability With internal oscillator |
+/- 0.05 % |
With reserve synchronism |
+/- 3 % (from 1 to 5 % adjustable) |
Voltage stability (for 0 to 100 % load variation) Static |
+/-1 % (+/-2 % for parallel systems) |
Voltage stability (for 0 to 100 % load variation) Dynamic |
VFI SS 111 as per IEC/EN 62040-3, class 1 |
Inverter overload capability 1 minute |
150 % of nominal power |
Inverter overload capability 10 minutes |
125 % of nominal power |
Short-circuit clearance (in % of nominal current) |
1-ph output : 250 % / 100ms – 175% / 5s |
3-ph output Ph-N: |
315 % / 100 ms – 220 % / 5 s |
3-ph output Ph-Ph: |
190 % / 100 ms – 135 % / 5 s |
Harmonic voltage distorsion |
With 100 % linear load < 3 % |
Harmonic voltage distorsion |
With 100 % non-linear load : SS as per IEC/EN 62040-3 |
Allowable power factor |
0,5 lagging to 0,5 leading |
General Data |
|
Operating temperature |
0 to 40 °C (-20°…55°C on request) |
Storage temperature |
-20 to +70 °C |
Relative humidity |
< 95 % non condensing |
Operating altitude |
1000 m max without derating |
Cooling |
Forced ventilation |
Efficiency |
Up to 91 % according to rating |
External protection |
IP 20 according to IEC 60529 |
Internal protection |
Protection against unintentional direct contacts, as per IEC 60950-1 |
Noise (at 1m in front of the unit) |
60-75 dB according to rating |
Cabinet color |
Grey RAL 7032 |
Dimensions |
Varying according to ratings and options |
Ratings |
|
Output power (kVA) |
5 to 500 |
DC Input voltage (Vdc) |
110-220 | 220-240 | 400 |
Options |
|
Inverter |
Automatic precharge of capacitors Onther output voltage (1 x 110 to 3 x 690 VAC) Inverter oversizing |
Bypass line |
Bypass isolator(s) Bypass transformer (H class) Bypass stabilizer (servo-controlled) Backfeed protection |
System |
Inverter with or with bypass line Parallel configurations Input / output isolators AC Distribution Earth fault detection or monitoring Internal lighting Anti-condensation heater Cabinet temperature monitor |
Mechanical |
External ingress protection up to IP42 Top cable entry Specified color of panels Special feet height (200mm or 300mm) Special keylock Non-magnetic gland plate (brass or aluminum) Lifting eyes 2 mm side panels thickness Specified cabinet identification (tag, nameplate) Anti-seismic design |
Communication |
Front panel analogue meters(72×72, class 1.5 or class 1) Transducers 4-20mA Additional volt-free contacts Modbus RTU (RS232 or RS485) Modbus / TCP Profibus IEC61850 protocol PPVis monitoring software Mimic panel on front:• Passive mimic of the system• Active mimic with integrated LEDs Lamp indicator on front panel (22 mm diameter) |
Standards |
IEC62040-1:2008+AMD1:2013 IEC62040-2:2006 IEC62040-3:2011 IEC61439-1:2011 IEC60529:1989+AMD1:1999 IEC60076-11:2004 |
Copyright © 2023 EDPN Services & System Co., Ltd by A&B Viet Nam. All Rights Reserved.