Chloride® CP70i DC/AC Inverter
Battery Monitoring System (BMS) - ATEX/IECEx
Innovative SMC/Salt Batteries & UPS Integration
Battery Monitoring System (BMS) - ATEX/IECEx
Single Cell MC/MB NiCad battery
Single Cell LCE / LB NiCad battery
Single Cell HC/ HB NiCad Battery
CleverWatch™ advanced NiCad battery remote monitoring solution
UPS Adapter CS141 Professional
UPS Adapter CS141 Budget / Budget LC
UPS Adapter CS141 HW161 Update
BAS - Battery Analyse System (On Demand)
For Manufacturers: SMARTBATTERY
EDPN IBAD-2612-ED Intelligent Battery Charge & Discharge Unit
EDPN 110LB120-T Battery Capacity Tester
EDPN 220LB300-T Battery Capacity Tester
EDPN 220LB150-K Battery Capacity Tester
EDPN 110LB300-K Battery Capacity Tester
EDPN 48LB150-K Battery Capacity Tester
CP as Customized Product. The most advanced product in terms of possibilities.
AC IEC/UL
5 to 500+ kVA
SCR/IGBT
Availability |
|
Maintainability | The easiest on the market with total components front access |
Reliability |
Innovative internal temperature reduction, through dual redundant cooling channels Multiplied redundancy with Chloride® Patented Smart Parallel Switching function that dynamically controls paralleled systems |
Key advantages |
|
User friendly |
Large color touch screen with 2000-event exportable log One of the best on the Industrial UPS Market |
USB access |
Export of all the recorded events using USB flash drive. Memorization of complete electronic settings for future maintenance needs |
Batteries compatibility |
Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries) Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion |
Low THDi |
6 – or 12-pulse thyristor rectifier Down to 5% THDI in 12-pulse SCR system with harmonic filters |
Life time |
Designed for 20+ years of continuous operation with appropriate maintenance plan |
Input |
|
AC Voltage |
3 X 400 V (380, 415) (other available on request) |
Voltage Tolerance |
+/- 10% |
Frequency |
50 Hz (60 Hz) |
Frequency Tolerance |
+/- 5% |
Inrush current |
≤ 10 x ln (other available on request) |
Output |
|
AC voltage Single-phase |
1 x 230 V (220, 240) | 1 x 110 V (115, 120) (other available on request) |
AC voltage Three-phase |
3 x 400 V (380, 415) | 3 x 220 V (200, 208, 230) (other available on request) |
Frequency |
50 Hz (60 Hz) |
Frequency stability With internal oscillator |
+/- 0.05 % |
Frequency stability with reserve synchronism |
+/- 3 % (from 1 to 5 % adjustable) |
Voltage stability (for 0 to 100 % load variation) Static |
+/-1 % (+/-2 % for parallel systems) |
Voltage stability (for 0 to 100 % load variation) Dynamic |
VFI SS 111 as per IEC/EN 62040-3, class 1 |
Inverter overload capability 1 minute |
150 % of nominal power |
Inverter overload capability 10 minutes |
125 % of nominal power |
Short-circuit clearance (in % of nominal current) |
1-ph output: 250 % / 100ms – 175% / 5s |
Short-circuit clearance (in % of nominal current) |
3-ph output Ph-N: 315 % / 100 ms – 220 % / 5 s |
Short-circuit clearance (in % of nominal current) |
3-ph output Ph-Ph: 190 % / 100 ms – 135 % / 5 s |
Harmonic voltage distortion: With 100% linear load |
< 3% |
Harmonic voltage distortion: With 100% non-linear load |
SS as per IEC/EN 62040-3 |
Allowable power factor |
0,5 lagging to 0,5 leading |
Battery |
|
Type |
Salt Metal Chloride, Lead acid or nickel cadmium, vented or recombination |
Autonomy |
From few minutes to several hours, on request |
Battery current limitation (typical, float, & boost modes) |
0.1 C (lead-acid battery) / 0.2 C (nickel-cadmium battery) |
General Data |
|
Operating temperature |
0 to 40 °C (-20°…55°C on request) |
Storage temperature |
-20 to +70 °C |
Relative humidity |
< 95 % non condensing |
Operating altitude |
1000 m max without derating |
Cooling |
Forced ventilation |
Efficiency |
Up to 90% according to rating |
External protection |
IP 20 according to IEC 60529 |
Internal protection |
Protection against unintentional direct contacts, as per IEC 60950-1 |
Noise (at 1m in front of the unit) |
60-75 dB according to rating |
Cabinet color |
Grey RAL 7032 |
Dimensions |
Varying according to ratings and options |
Ratings |
|
110-120 Vdc |
5 / 10 / 20 / 30 / 40 / 50 / 60 kVA |
220-240 Vdc |
10 / 20 / 30 / 40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 250 / 320 / 400 / 500 kVA |
400 Vdc |
40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 250 / 320 / 400 / 500 kVA |
Standards |
|
IEC62040-1:2017 |
Uninterruptible power systems (ups) – Part 1: Safety requirements |
IEC62040-2:2016 |
Uninterruptible power systems (UPS) -Part 2: Electromagnetic compatibility (EMC) requirements |
IEC62040-3:2011 |
Uninterruptible power systems (UPS) – Part 3: Method of specifying the performance and test requirements |
IEC61439-1:2011 |
Low voltage switchgear and controlgear assemblies – Part 1: General rules |
IEC60529:1989+AMD1:1999 |
Degrees of protection provided by enclosures (IP Code) |
IEC60076-11:2004 |
Power transformers – Part11: Dry type transformers |
Conformity |
|
Low voltage directive |
2006/95/EC and 2014/35EU |
EMC directive |
2004/108/EC and 2014/30/EU |
CE Mark |
Yes |
Options(Consult us for any other requirements, subject to feasibility) |
|
Rectifier-charger |
• 12-pulse rectifier • Harmonic filter on 12P for THDi ≈5 % (+/- 1pt) • Voltage ripple filter • Blocking diode • Other input voltage (3 x 190 to 3 x 690 VAC) • Surge and/or lightning protections • Rectifier output switch |
Battery line |
• Battery circuit protection box • Battery reversed polarity detection • Battery low-voltage disconnection • DC earth fault detection • Battery black start • Battery room temperature sensor • Battery monitoring system (Chloride® BMS) • Battery cabinet / rack |
Inverter |
• Other output voltage (1 x 110 to 3 x 690 VAC) • Manual or automatic precharge of inverter capacitors • Inverter input switch |
Bypass line |
• Bypass isolator(s) • Bypass transformer (H class) • Bypass stabilizer (servo-controlled) • Backfeed protection • Surge and/or lightning protections |
System |
• Dual distributed parallel configuration with one or two reserve lines • Input / output isolators • AC distribution • AC earth fault detection or monitoring • Internal cabinet lighting • Anti-condensation heater • UPS cabinet temperature monitor |
Mechanical |
• External ingress protection up to IP42 • Top cable entry • Specified color of panels • Special feet height (200mm or 300mm) • Special keylock • Non-magnetic gland plate (brass or aluminum) • 2 mm side panels thickness • Specified cabinet identification (tag, nameplate) |
Communication |
• Front panel analogue meters (72×72, class 1.5) • Transducers 4-20mA • Additional volt-free contacts • Modbus RTU (RS232 or RS485) • Modbus / TCP • Profibus • IEC61850 protocol • PPVis monitoring software • Mimic panel: – Passive mimic of the system – Active mimic with integrated LEDs • Lamp indicator on front panel (22 mm diameter) |
Copyright © 2023 EDPN Services & System Co., Ltd by A&B Viet Nam. All Rights Reserved.