Chloride® CP70i DC/AC Inverter
Battery Monitoring System (BMS) - ATEX/IECEx
Innovative SMC/Salt Batteries & UPS Integration
Battery Monitoring System (BMS) - ATEX/IECEx
Single Cell MC/MB NiCad battery
Single Cell LCE / LB NiCad battery
Single Cell HC/ HB NiCad Battery
CleverWatch™ advanced NiCad battery remote monitoring solution
UPS Adapter CS141 Professional
UPS Adapter CS141 Budget / Budget LC
UPS Adapter CS141 HW161 Update
BAS - Battery Analyse System (On Demand)
For Manufacturers: SMARTBATTERY
EDPN IBAD-2612-ED Intelligent Battery Charge & Discharge Unit
EDPN 110LB120-T Battery Capacity Tester
EDPN 220LB300-T Battery Capacity Tester
EDPN 220LB150-K Battery Capacity Tester
EDPN 110LB300-K Battery Capacity Tester
EDPN 48LB150-K Battery Capacity Tester
Chloride® XP DC/AC UPS Inverter systems are tailor-made solutions designed to operate in the hazardous atmosphere.
DC/AC Inverter IECEx
< 80 kVA
IGBT
Key advantages |
|
Small footprint |
To optimize space on offshore platform |
Durability |
Optimized thermal management |
Immunity |
Strong immunity to perturbations |
Safe control, door closed |
allows the user to operate the switches, circuit breakers, and control buttons door closed |
Smart access to data |
Large graphical user interface on the front |
Safe and easy maintenance |
Once open, the front door gives direct access to all components |
Alarms |
Embedded event logger (up to 2000 events) Close range Wi-Fi module – To download the event logger without opening the equipment enclosure |
Input |
|
AC voltage |
3 x 400 V (380, 415) |
Voltage tolerance | +/- 10 % |
Frequency | 50 Hz (60 Hz) |
Frequency tolerance |
+/- 5 % |
Output |
|
AC voltage |
1 x 230V (220, 240) 1 x 110V (115, 120) 3 x 400 V (380, 415) |
Frequency |
50 Hz (60 Hz) |
Overload inverter: 1 minute |
150 % of nominal power |
Overload inverter: 10 minutes |
125 % of nominal power |
Short circuit clearance: 1-ph output (in % of nominal current) |
250 %/100 ms – 175 %/5 s |
Short circuit clearance: 3-ph output (in % of nominal current) |
315 %/100 ms – 220 %/5 s (Ph-N) |
Power factor |
0.8 lagging |
Allowable crest factor |
3/1 |
Battery |
|
Type |
Valve Regulated Lead Acid (VRLA) Recombinaison Nickel Cadmium |
Autonomy |
From few minutes to several hours, as per customer’s requirement |
Battery current limitation (typical, float, mode) |
0.1 (Lead Acid or Nickel Cadmium battery) |
Battery temperature compensation |
-3 mV / °C / cell |
General Data |
|
Operating temperature |
up to 55°C |
Relative humidity |
100% condensing |
Operating altitude |
1000m max without derating |
Cooling |
Natural |
Enclosure |
|
Design |
ATEX/IECex certified forZone1, II 2G Ex d IIB+H2 T3 (IEC 60079) |
Material |
Stainless steel (SS316L),Carbon steel (mild steel) or Aluminum |
External ingress protection |
IP 66 according to IEC 60529 |
Dimensions |
Varying according to ratings & options |
Copyright © 2023 EDPN Services & System Co., Ltd by A&B Viet Nam. All Rights Reserved.