Chloride® XP20R is an industrial rectifier / battery charger explosion proof Zone 1 & 2 developed specifically for offshore environment & tough operating conditions. It is the smallest DC UPS of XP range.
DC UPS ATEX/IECEx
< 1800W
SMR
Key advantages |
|
Small footprint |
To optimize space on offshore platform |
Durability |
Optimized thermal management |
Immunity |
Strong immunity to perturbations |
Safe control, door closed |
allows the user to operate the switches, circuit breakers, and control buttons door closed |
Smart access to data |
Large graphical user interface on the front |
Safe and easy maintenance |
Once open, the front door gives direct access to all components |
Alarms |
Embedded event logger (up to 2000 events) Close range Wi-Fi module – To download the event logger without opening the equipment enclosure |
Input |
|
AC voltage |
1 x 230 V (220, 240) |
Voltage tolerance |
+15% / -18% (187 V to 264 V) |
Neutral configuration | Any configuration, with or without neutral |
Frequency |
50 Hz (60 Hz) |
Frequency range |
From 47 Hz to 63 Hz |
Total harmonic current distortion (THDi) |
≤ 5% |
Inrush current |
≤ 10 x In |
Input power factor |
≤0.95 |
Output |
|
Nominal DC Voltage |
24 V / 48 V |
Output DC voltage range |
+/-15 % |
Static regulation |
+/-1 % |
Voltage ripple |
≤ 0.1 % RMS (disconnected battery) |
Current limitation |
I nominal |
Charging mode |
With valve regulated lead acid: single charge mode With recombination nickel cadminum: single charge mode (recommended) or dual charge mode |
Charging current |
With valve regulated lead acid : 0.05C10 to 0.1C With recombination nickel cadmium: 0.1C (up to 0.2C subject to battery enclosure certification limits) |
Protections |
|
Input |
type : MCCB Breaking capacity : 18 kA Lightning arrestor / spike suppressor |
Battery |
pre-heating start-up type : MCCB Breaking capacity : 18 kA Battery reverse polarity protection Low Voltage Disconnection (LVD) device External battery cut-off |
Output |
type: MCCB Breaking capacity: 18 kA |
Isolation Voltage |
Input / output: 4200 Vdc / 1 min Input / ground: 2300 Vdc / 1 min Output / ground: 1500 Vdc / 1 min |
System |
Internal anti-condensation paint Conformal coating of Printed Circuit Boards (PCB) Volatile Corrosion Inhibitot (VCI) for 2 years |
|
|
Battery |
|
Type |
Valve regulated lead acid |
Autonomy |
from few minutes to several hours, upon requirement |
|
|
Ratings |
|
Output voltage |
24 Vdc 48 Vdc |
Output current |
24 Vdc ==> 15, 25 , 50A 48 Vdc ==> 15, 25 A |
General Data |
|
Execution |
II 2 G Ex db eb IIB+H2 T5 Gb IP66 |
External ingress pprotection |
IP 66 |
Rectifier efficiency |
From 86 % (24 V) to 89 % (48 V) |
Operating temperature |
From 0 °C to 50 °C (external temperature, without derating) |
Storage temperature |
From -20 °C to +70 °C (battery excluded) |
Relative humidity |
100 %, condensing |
Operating altitude |
1000 m (without system derating) |
Cooling |
Natural convection |
Noise |
≤ 30 dB (at 1m in front of the unit) |
Dimensions
|
W: 490 mm / D: 491 mm / H: 1200 mm |
Weight |
Varying according to ratings and options |
Installation |
Vertically wall-mounted |
Design life |
20 years |
Materials |
Charger enclosure: Ex d, copper-free marine grade aluminum Customer terminal box: Ex e, stainless steel 316L Supporting frame: C35 steel |
Painting |
External: C5 marine-grade painting, RAL 7035 or 7032Internal: Hygroscopic orange RAL 2004 |
Customer connection |
Through pre-dilled gland plate, 1.5mm thickness |
Standards |
|
Standards |
IEC EN 60146-1-1:2009 IEC EN 61000-6-2:2006 IEC EN 61000-6-4:2007 AMD1:2011 IEC EN 61439-1:2011 IEC EN 60529:1989 AMD1:1999 NFC 58-311:1990 IEC EN 60079-0 IEC EN 60079-1 IEC EN 60079-7 |