EDPN SERVICES & SYSTEM · CRITICAL POWER SYSTEMS · VIETNAM
Chloride · Industrial DC Critical Power

Chloride® CP70R - DC UPS

CP as Customized Product. A natural cooled product.

UPS TypeDC UPS / Natural cooling
Ratings24...220 Vdc | 25...2000A
TechnologySCR
INDUSTRIAL DC CRITICAL POWERCHLORIDE
Chloride® CP70R - DC UPS — manufacturer product image
MANUFACTURER PRODUCT IMAGESUPPLY · COMMISSIONING · SERVICE
OverviewFeaturesVideoSpecificationsDownloadsEDPN projectsMore models
OVERVIEW

Chloride® CP70R - DC UPS.

APPLICATIONS
Power generation plantsTransmission and Distribution substationsContinuous process industriesOil & Gas and Petrochemical industriesRail transport
FEATURES

Features & benefits.

Key advantages

  • User friendly Large color touch screen with 2000-event exportable log.
  • USB access Export of all the recorded events using USB flash drive. Memorization of complete electronic settings for future maintenance needs.
  • Batteries compatibility Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries). Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion.
  • Life time Designed for 20+ years of continuous operation with appropriate maintenance plan.
  • Inrush current Reduced ≤ 10xIn to avoid oversizing upstream protection and 2-step strat-up.
VIDEO

CP70R options.

The video is loaded from YouTube (youtube-nocookie.com) only after you press play. Google may then receive your IP address and set cookies under its own policy — see our Cookie Policy.

SPECIFICATIONS

Technical data.

Summarised from the manufacturer’s published data. Confirm the current datasheet and the project specification before selection.

Input

AC voltageSingle phase 1 x 230 V (220, 240)
Three phase3 x 400 V (380, 415)
Voltage tolerance+/- 10 %
Neutral configurationAny configuration, with or without neutral
Frequency50 Hz (60 Hz)
Frequency tolerance+/- 5 %
Frequency range (temporary)45 Hz to 65 Hz (with 50 Hz nominal)
Total harmonic current distorsion (THDI)< 34 % (6-pulse version)< 34 % (6-pulse version)
Inrush current< 15 x In (for 6-pulse and 12-pulse)

Output

Nominal DC voltage24...400V
Output DC voltage range17...550 V
Voltage stability (in stabilized floating mode, input within tolerance)Unitary system +/-1 %
Parallel systems+/-1 % to +/-2 %
Voltage ripple≤ 1 % RMS, in float mode, battery disconnected
Current limitationI nominal

Battery

TypeSalt Metal Chloride, Lead acid or nickel cadmium, vented or recombination
AutonomyFrom few minutes to several hours, on request
Battery current limitation (typical, float, & boost modes)0.1 C (lead-acid battery) / 0.2 C (nickel-cadmium battery)

General data

Operating temperature0 to 40 °C (-20°...55°C on request)
Storage temperature-20 to +70 °C
Relative humidity< 95 % non condensing
Operating altitude1000 m max without derating
CoolingNatural convection on most of the range
EfficiencyUp to 96 % according to rating
External protectionIP 20 according to IEC 60529
Internal protectionProtection against unintentional direct contacts, as per IEC 60950-1
Noise (at 1m in front of the unit)55 – 65 dB according to rating
Cabinet colorGrey RAL 7032
DimensionsVarying according to ratings & options

Ratings

1 phase input24 Vdc ... 127 Vdc
2 phase input25...250 Vdc
3 phase input24 Vdc...400Vdc
3 phase output25 A ... 2500 A
DOWNLOADS

Datasheets & documents.

Product information source: Chloride — official product page ↗. Specifications and documents belong to the manufacturer and may change; EDPN confirms the configuration for each project.

EDPN PROJECTS

Where EDPN has worked with this product.

ALL PROJECTS & REFERENCES →
INDUSTRIAL DC UPS

More models in this range.

ALL 4 MODELS →
LIFECYCLE SERVICES

Lifecycle services for this product.

ALL SERVICES →
CONTACT EDPN

New project or installed equipment?

Send the specification for a new project, or equipment details for service support.