EDPN SERVICES & SYSTEM · CRITICAL POWER SYSTEMS · VIETNAM
Chloride · Industrial DC Critical Power

Chloride® CP70RC - DC UPS

CP as Customized Product. A force cooled product.

UPS TypeDC UPS / Forced cooling
Ratings24...220 Vdc | 200...1300A
TechnologySCR
INDUSTRIAL DC CRITICAL POWERCHLORIDE
Chloride® CP70RC - DC UPS — manufacturer product image
MANUFACTURER PRODUCT IMAGESUPPLY · COMMISSIONING · SERVICE
OverviewFeaturesVideoSpecificationsDownloadsMore models
OVERVIEW

Chloride® CP70RC - DC UPS.

APPLICATIONS
Oil and Gas industries, offshore and onshoreRefining and petrochemical plantsPower generation plantsRail transportProcess industries
FEATURES

Features & benefits.

Key advantages

  • Maintainability The easiest on the market with total components front access.
  • Reliability Innovative internal temperature reduction, through dual redundant cooling channels. Multiplied redundancy with Chloride® Patented Smart Parallel Switching function that dynamically controls paralleled systems.
  • User friendly Large color touch screen with 2000-event exportable log.
  • USB access Export of all the recorded events using USB flash drive. Memorization of complete electronic settings for future maintenance needs.
  • Batteries compatibility Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries). Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion.
  • Life time Designed for 20+ years of continuous operation with appropriate maintenance plan.
  • Inrush current Reduced ≤ 10xIn to avoid oversizing upstream protection and 2-step strat-up.
  • Cooling Forced ventilation to reduce the foot print.
VIDEO

CP70RC options.

The video is loaded from YouTube (youtube-nocookie.com) only after you press play. Google may then receive your IP address and set cookies under its own policy — see our Cookie Policy.

SPECIFICATIONS

Technical data.

Summarised from the manufacturer’s published data. Confirm the current datasheet and the project specification before selection.

Input

AC voltage3 x 400 V (380, 415)
Voltage tolerance+/- 10 %
Neutral configurationAny configuration, with or without neutral
Frequency50 Hz (60 Hz)
Frequency tolerance+/- 5 %
Frequency range (temporary)45 Hz to 65 Hz (with 50 Hz nominal)
Total harmonic current distorsion (THDI)< 34 % (6-pulse version)< 10 % (12-pulse version)
Inrush current< 10 x In (for 6-pulse and 12-pulse)< 5 x In (for 12-pulse + harmonic filter option)

Output

Nominal DC voltage24 V ; 48 V ; 110-127 V ; 220-240 V ; 400 V
Output DC voltage range17-40 V ; 36-75 V ; 88-160 V ; 176-300 V ; 296-550 V
Voltage stability (in stabilized floating mode, input within tolerance)Unitary system +/-1 %
Voltage stability (in stabilized floating mode, input within tolerance)Parallel systems +/-1 % to +/-2 %
Voltage ripple≤ 1 % RMS, in float mode, battery disconnected
Current limitationI nominal

Battery

TypeSalt Metal Chloride, Lead acid or nickel cadmium, vented or recombination
AutonomyFrom few minutes to several hours, on request
Battery current limitation (typical, float, & boost modes)0.1 C (lead-acid battery) / 0.2 C (nickel-cadmium battery)

General data

Operating temperature0 to 40 °C (-20°...55°C on request)
Storage temperature-20 to +70 °C
Relative humidity< 95 % non condensing
Operating altitude1000 m max without derating (other available on request)
CoolingForced ventilation
Efficiency81 % to 97 % according to rating
External protectionIP 20 according to IEC 60529 (other available on request)
Noise (at 1m in front of the unit)60-72 dB according to rating
Cabinet colorGrey RAL 7032 (other available on request)
DimensionsVarying according to ratings & options

Ratings

Output voltage 24 VdcOutput current (A) 200...1200
Output voltage 48 VdcOutput current (A) 200...1200
Output voltage 110-127 VdcOutput current (A) 200...1200
Output voltage 220-240 VdcOutput current (A) 200...1200
Output voltage 400 VdcOutput current (A) 200...1200
DOWNLOADS

Datasheets & documents.

Product information source: Chloride — official product page ↗. Specifications and documents belong to the manufacturer and may change; EDPN confirms the configuration for each project.

INDUSTRIAL DC UPS

More models in this range.

ALL 4 MODELS →
LIFECYCLE SERVICES

Lifecycle services for this product.

ALL SERVICES →
CONTACT EDPN

New project or installed equipment?

Send the specification for a new project, or equipment details for service support.