EDPN SERVICES & SYSTEM · CRITICAL POWER SYSTEMS · VIETNAM
Chloride · Industrial DC Critical Power

Chloride® FP50R - DC UPS

Designed to provide a simple, fast and cost effective solution for DC power requirements.

TypeDC UPS / Natural cooling
Ratings24...125 Vdc | 10...250 A
TechnologySCR
INDUSTRIAL DC CRITICAL POWERCHLORIDE
Chloride® FP50R - DC UPS — manufacturer product image
MANUFACTURER PRODUCT IMAGESUPPLY · COMMISSIONING · SERVICE
OverviewFeaturesSpecificationsDownloadsMore models
OVERVIEW

Chloride® FP50R - DC UPS.

APPLICATIONS
Power Transmission and Distribution (Motorised circuit breakers, control rooms, SCADA, automatic controllers)Energy Production (Safety systems, SCADA, automatic controllers)Process Industries (Control systems, SCADA, automatic controllers)
FEATURES

Features & benefits.

Key Advantages

  • More reliable Thanks to the proven thyristor technology that Chloride® has mastered for over 70 years.
  • More robust With a natural cooling design throughout the range. No risk of fan-related failures.
  • Less maintenance Due to the use of long-life components.
  • Easier to use With its human-machine interface featuring a large, high-contrast display. The display shows the rectifier diagram and indicates any faults, which are also indicated by summary LEDs.
  • Faster availability Thanks to its design in 100% industrialised configurable sub-assemblies. Lead time is confirmed with each quotation.
SPECIFICATIONS

Technical data.

Summarised from the manufacturer’s published data. Confirm the current datasheet and the project specification before selection.

Range

1-Phase10/25/40/60/100 Adc
3-Phase25/40/60/100/160/250 Adc

Input

Rated voltage1-Phase: 230Vac (220,240) 3-Phase: 400Vac (380,415) / 208Vac
Input voltage tolerance± 10%
Frequency47Hz / 63Hz
Frequency tolerance± 5%
Inrush current1-Ph: < 15 ln 3-Ph: < 10 ln

Output

Rated voltage DC24V (17V-34V), 48V (34V-68V), 110-125V (88V-179V)
Voltage stability (in stabilised floating mode, input within tolerances)Single system: ± 1% Dual system: ± 1% to ± 2%
Voltage ripple rate≤ 5 % at 100 % load

Battery

TypeLead-Acid or Nickel-Cadmium, VLA or VRLA
AutonomyFrom a few minutes to several hours, on request
24V - Number of battery cellsLead-Acid: 12 NiCd: 18 - 20
48V - Number of battery cellsLead-Acid: 24 NiCd: 36 - 44
110V - Number of battery cellsLead-Acid: 54 NiCd: 82 - 92
125V - Number of battery cellsLead-Acid: 60 NiCd: 91–105

General Data

Operating temperature0 to 40°C (2)
Storage temperature range-20 to 70°C (excluding battery)
Relative humidity< 95% non-condensing at 20°C
Altitude1000m (2) (without downgrading the system)
Rectifier technologySCR, 2-pulses thyristors
CoolingNatural convection
External protection classIP21 to IEC 60529 (other protection classes available: IP41 / IP42)
Internal protectionProtection against unintentional direct contact according to IEC 62477-1
Cabinet coloursGrey RAL 7035 / Grey RAL 7032
DimensionsVaries according to size and options

Monitoring

Local, on the front panelGraphic display with navigation buttons (75mm x 45mm)
List of relay alarmsStandards: general alarm, mains failure, battery charging, end of discharge Options: ground fault, boost mode, overvoltage, undervoltage
Alarm relays, contact characteristicsChangeover contact, switching capacity in accordance with DIN VDE 0660/IEC 60947: 1 A (24 V (DC13)), 0.2 A (110 V, DC13), 0.1 A (220 V, DC13) 3 A (24 V, AC15), 3 A (120 V, AC15), 3 A (230 V, AC15)
Remote control (optional)RS485, TCP-IP, IEC 61850*, SNMP*, PROFIBUS *under development, consult us

Standards

IEC 61000-6-2: 2016Electromagnetic compatibility (EMC) - Part 6-2: General requirements - Emission for industrial environments.
IEC 61000-6-4: 2018Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission for industrial environments.
IEC 61000-6-5: 2015Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Emission for equipment used in power plant and substation environments.
IEC 62477-1: 2022Safety requirements for electronic power conversion systems and equipment - Part 1: General.
IEC 60146-1-1: 2009Semiconductor converters - General requirements and mains switched converters - Part 1-1: Specification of basic requirements.
IEC 60529: 2013Degrees of protection provided by the enclosures (IP Code).
DOWNLOADS

Datasheets & documents.

Product information source: Chloride — official product page ↗. Specifications and documents belong to the manufacturer and may change; EDPN confirms the configuration for each project.

INDUSTRIAL DC UPS

More models in this range.

ALL 4 MODELS →
LIFECYCLE SERVICES

Lifecycle services for this product.

ALL SERVICES →
CONTACT EDPN

New project or installed equipment?

Send the specification for a new project, or equipment details for service support.