EDPN SERVICES & SYSTEM · CRITICAL POWER SYSTEMS · VIETNAM
Chloride · Industrial AC Critical Power

Chloride® CP70Z - AC UPS

CP as Customized Product.

UPS TypeAC IEC/NEMA
Ratings5 to 500+ kVA
TechnologySCR/IGBT
INDUSTRIAL AC CRITICAL POWERCHLORIDE
Chloride® CP70Z - AC UPS — manufacturer product image
MANUFACTURER PRODUCT IMAGESUPPLY · COMMISSIONING · SERVICE
OverviewFeaturesVideoSpecificationsDownloadsEDPN projectsMore models
OVERVIEW

Chloride® CP70Z - AC UPS.

APPLICATIONS
Oil & Gas industries, offshore and onshoreRefining and petrochemical plantsPower generation plantsRail transportProcess industries
FEATURES

Features & benefits.

Key advantages

  • Maintainability The easiest on the market with total components front access.
  • Reliability Innovative internal temperature reduction, through dual redundant cooling channels. Multiplied redundancy with Chloride® Patented Smart Parallel Switching function that dynamically controls paralleled systems.
  • User friendly Large color touch screen with 2000-event exportable log.
  • USB access Export of all the recorded events using USB flash drive. Memorization of complete electronic settings for future maintenance needs.
  • Batteries compatibility Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries). Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion.
  • Low THDi 6 - or 12-pulse thyristor rectifier. Down to 5% THDI in 12-pulse SCR system with harmonic filters.
  • Life time Designed for 20+ years of continuous operation with appropriate maintenance plan.
VIDEO

CP70Z presentation.

The video is loaded from YouTube (youtube-nocookie.com) only after you press play. Google may then receive your IP address and set cookies under its own policy — see our Cookie Policy.

SPECIFICATIONS

Technical data.

Summarised from the manufacturer’s published data. Confirm the current datasheet and the project specification before selection.

Input

AC Voltage3 X 400 V (380, 415) (other available on request)
Voltage Tolerance+/- 10%
Frequency50 Hz (60 Hz)
Frequency Tolerance+/- 5%
Inrush current≤ 10 x ln (other available on request)

Output

AC Voltage Single phase1 x 230 V (220, 240) ; 1 x 110 V (115, 120) (other available on request)
AC Voltage Three phase3 x 400 V (380, 415) ; 3 x 220 V (200, 208, 230) (other available on request)
Frequency50 Hz (60 Hz)
Frequency stability with internal oscillator+/- 0.05%
Frequency stability with reserve synchronism+/- 3 % (from 1 to 5% adjustable)
Voltage stability (for 0 to 100 % load variation): DynamicVFI SS 111 as per IEC/EN 62040-3, class 1
Inverter overload capability: 1 minute150 % of nominal power
Inverter overload capability: 10 minutes125 % of nominal power
Short circuit clearance (in % of nominal current): 1-ph output250 % / 100 ms - 175 % / 5s
Short circuit clearance (in % of nominal current): 3-ph output Ph-N315 % / 100 ms - 220 % / 5s
Short circuit clearance (in % of nominal current): 3-ph output Ph-Ph190 % / 100 ms - 135 % / 5s
Harmonic voltage distortion: With 100% linear load< 3%
Harmonic voltage distortion: With 100% non-linear loadSS as per IEC/EN 62040-3
Allowable power factor0.5 lagging to 0.5 leading

Battery

BatterySalt Metal Chloride, Lead acid or nickel cadmium, vented or recombination
AutonomyFrom few minutes to several hours, on request
Battery current limitation (typical, float, & boost modes)0.1 C (lead-acid battery) / 0.2 C (nickel-cadmium battery)

General Data

Operating temperature0 to 40 °C (-20°...55°C on request)
Storage temperature-20 to +70°C
Relative humidity< 95% non condensing
Operating altitude1000m max without derating (other available on request)
CoolingForced ventilation
EfficiencyUp to 90% according to rating
External protectionIP 20 according to IEC 60529 (other available on request)
Internal protectionProtection against unintentional direct contact, as per IEC 60590-1/62477-1
Cabinet colourGrey RAL 7032 (other available on request)
DimensionsVarying according to ratings and options

Ratings

110-120 Vdc5 / 10 / 20 / 30 / 40 / 50 / 60 kVA
220-240 Vdc10 / 20 / 30 / 40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 250 / 320 kVA
400 Vdc40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 250 / 320 / 400 / 500 kVA

Standards

IEC62040-1:2017Uninterruptible power systems (ups) - Part 1: Safety requirements
IEC62040-2:2016Uninterruptible power systems (UPS) -Part 2: Electromagnetic compatibility (EMC) requirements
IEC62040-3:2011Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
IEC61439-1:2011Low voltage switchgear and controlgear assemblies - Part 1: General rules
IEC60529:1989+AMD1:1999Degrees of protection provided by enclosures (IP Code)
IEC60076-11:2004Power transformers - Part11: Dry type transformers

Conformity

Low voltage directive2006/95/EC and 2014/35EU
EMC directive2004/108/EC and 2014/30/EU
CE MarkYes

Options

Wide range of optionsRefer to datasheet in download section
DOWNLOADS

Datasheets & documents.

Product information source: Chloride — official product page ↗. Specifications and documents belong to the manufacturer and may change; EDPN confirms the configuration for each project.

EDPN PROJECTS

Related EDPN project experience.

ALL PROJECTS & REFERENCES →
INDUSTRIAL AC UPS

More models in this range.

ALL 3 MODELS →
LIFECYCLE SERVICES

Lifecycle services for this product.

ALL SERVICES →
CONTACT EDPN

New project or installed equipment?

Send the specification for a new project, or equipment details for service support.