UPS TypeAC IEC/NEC
Ratings5 to 80 kVA
TechnologyFull IGBT
INDUSTRIAL AC CRITICAL POWERCHLORIDE
Chloride® FP70ZE - AC UPS — manufacturer product image
MANUFACTURER PRODUCT IMAGESUPPLY · COMMISSIONING · SERVICE
OverviewFeaturesVideoSpecificationsDownloadsMore models
OVERVIEW

Chloride® FP70ZE - AC UPS.

APPLICATIONS
Decarbonisation (Solar, CCS, H2, Wind Turbines)Petrochemical and ChemicalMinings/MetalsPower generation plantsWater and WastewaterTransportation (rail, metro, tramway)Continuous manufacturing processes
FEATURES

Features & benefits.

Key advantages

  • Footprint Compact footprint -20% to -45% vs traditional technologies
  • CO2 footprint Reduction up to -25%
  • Battery innovation Sodium Metal Chloride (SMC) batteries integration
  • Safety Bidirectional rectifier to perform battery deep discharging.
  • Smart access to UPS data Large color HMI touch-pad for better user interface.
  • USB access Export of all the recorded events using USB flash drive.
  • Performance designed to optimize expenses Reduced CAPEX - Upstream transformer, switchgear and cables are downsized thanks to high input power factor, low THDi rejection and low inrush current. Proven digital Vector Control technology to control the output waveform, even on non linear loads.
  • Controlled OPEX Lower power consumption thanks to high efficiency
  • Industrial-grade maintainability Innovative design allowing an easy front access to all components.
  • Industrial flexibility Fit-for-purpose battery selection. Galvanic isolation: either output and/or input transformers. Wide range of electrical and mechanical options.
VIDEO

FP70ZE presentation.

The video is loaded from YouTube (youtube-nocookie.com) only after you press play. Google may then receive your IP address and set cookies under its own policy — see our Cookie Policy.

SPECIFICATIONS

Technical data.

Summarised from the manufacturer’s published data. Confirm the current datasheet and the project specification before selection.

Input

AC Voltage3-ph+N 208...690 Vac ph-ph ± 10 % (tolerances depend on the voltages)
Inrush current≤ 1 In (without input transformer) ≤ 15 In (with input transformer)
Power factorUp to 0.99
Frequency range50 Hz (60 Hz factory setting) ± 5 %
Embedded input featuresAC input isolator switch Surge protection with MOV lightning arrestors
Max allowed voltage distortion, THDv from mains8%

Output

AC Voltage1-ph: 230 Vac (208, 220, 240) ; 110 Vac (115, 120, 127) 3-ph: 400 Vac (380, 415) ; 208 Vac (190, 200, 220)
Frequency stabilityWith internal oscillator ± 0.1 % With reserve synchronism ± 1 % (1 to 4 % adjustable)
Voltage stability (0-100% load variation)Static ± 1 % Dynamic VFI SS 11 as per IEC62040-3, class 1
Overload inverter (in % of nominal power)150 %/1 min - 125 %/10 min at nominal output voltage
Short-circuit clearance (in % of nominal current)1-ph: 260% /100 ms - 210% /5 s 3-ph: 380% /100 ms - 340% /5 s
Voltage distorsionWith 100 % linear load < 2 % With 100 % non linear load < 5 % as per IEC62040-3
Allowable power factor0.5 lagging to 0.5 leading
Allowable crest factor3/1
Embedded output featuresOutput switch Output isolation transformer class H

Battery

BatterySMC (Sodium Metal Chloride), Lead acid or nickel cadmium, vented or recombination
Recommended number of cells Lead Acid110 Vdc (52 to 72) 220 Vdc (104 to 132) 400 Vdc (174 to 220)
Recommended number of cells Nickel Cadmium110 Vdc (88 to 94) 220 Vdc (176 to 184) 400 Vdc (296 to 307)
Battery current limitation0.1 C (Lead Acid) / 0.2 C (Nickel Cadmium)
Embedded battery featuresInbuilt battery circuit breaker with aux. contact Battery reverse polarity protection and indication Battery Low Voltage Disconnection (LVD) Battery test, automatic or manual mode Battery room temperature sensor for battery charge compensation

General Data

EfficiencyUp to 91 % (according to rating and config.)
Operating temperatureFrom 0 to 40 °C (without system derating)
T°C operating / Storage0...40 °C without derating system / -20...70 °C battery excluded
Relative humidity< 95 % non condensing at 20 °C
Operating altitude1000 m (without system derating)
CoolingFan assisted
Ingress protectionInternal IP20 - external IP42
Noise (at 1m in front of the unit)62 to 72 dB (according to rating)
Input/output isolation2500 VAC / 1 minute
Feet100 mm height with feet cover
Gland plateAluminium non-magnetic, 3 mm thickness
Dimensions & colourFrom 1 x 800 mm to 2 x 1200 mm width / RAL 7035
Embedded system featuresInternal cabinet lighting / Lifting Eyes Auxiliary power socket
Display languagesEnglish, French, Spanish (factory settings)

Output Power (kVA)

110 Vdc5 / 10 / 20 kVA
220 Vdc10 / 20 / 30 / 40 / 50 / 60 kVA
400 Vdc40 / 50 / 60 / 80 kVA

Standards

IEC62040-1Semiconductor converters - Part 1-1: Specification of basic requirements
IEC62040-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industry
IEC62040-3Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission for industry
IEC61439-1Low voltage switchgear and controlgear assemblies - Part1: General rules
OtherType tests for rectifier-battery charger and batteries

Conformity

Low voltage directive2006/95/EC (before April 2016) 2014/35/EU (after April 2016)
EMC directive2004/108/EC (before April 2016) 2014/30/EU (after April 2016)
CE MarkYes

Intermediate DC Circuit

Nominal DC Voltage110 / 220 / 400 Vdc
Voltage stability in steady state≤ 1 % in float mode (input within tolerance)
Voltage ripple≤ 1 % RMS (with and without battery connected)
Current limitationI nominal
Charging characteristicIU according to DIN 41773

Options

RectifierInput isolation transformer Special 1-ph or 3-ph input voltage (up to 3 x 690 Vac) Input voltage tolerance from - 20 % to + 15 % Input circuit breaker with aux. contact and breaking capacity up to 70 kA Reverse phase sequence alarm Automatic input phase failure adaptation
BatteryProtection box (circuit breaker), black start, automatic or manual mode ; DC earth fault detection
OutputCircuit breaker with aux. contact Emergency Power Off
ReserveCircuit breaker with aux contact Reserve isolation transformer (H class) Reserve voltage stabilizer (servo-controlled) Stabilizer output isolator
SystemParallel configuration (distributed parallel) Operating temperature up to 50 °C with derating Operating altitude up to 4500 m with derating Redundant monitored fans Space heater with thermostat or hygrostat
MechanicalTop cable entry Special feet height 200 mm or base frame
CommunicationAdditional volt-free contacts (up to 20 relays) Modbus RTU (RS232 or RS485) ; TCP-IP / Profibus / SNMP PPVIS monitoring software
DOWNLOADS

Datasheets & documents.

Product information source: Chloride — official product page ↗. Specifications and documents belong to the manufacturer and may change; EDPN confirms the configuration for each project.