Chloride® XP20R is an industrial rectifier / battery charger explosion proof Zone 1 & 2 developed specifically for offshore environment & tough operating conditions. It is the smallest DC UPS of XP range.
Offshore production process in Explosion-risk areasWellhead platforms / Unmanned platformsPipelines instrumentationRefineries
FEATURES
Features & benefits.
Key features
Small footprint To optimize space on offshore platform.
Durability Optimized thermal management.
Immunity Strong immunity to perturbations.
Safe control, door closed Allows the user to operate the switches, circuit breakers, and control buttons door closed.
Smart access to data Large graphical user interface on the front.
Safe and easy maintenance Once open, the front door gives direct access to all components.
Alarms Embedded event logger (up to 2000 events). Close range Wi-Fi module - To download the event logger without opening the equipment enclosure.
VIDEO
Example of a Chloride explosion-proof UPS solution.
The video is loaded from YouTube (youtube-nocookie.com) only after you press play. Google may then receive your IP address and set cookies under its own policy — see our Cookie Policy.
SPECIFICATIONS
Technical data.
Summarised from the manufacturer’s published data. Confirm the current datasheet and the project specification before selection.
Input
AC Voltage
1 x 230 V (220, 240)
Voltage tolerance
+15% / -18% (187 V to 264 V)
Frequency
50 Hz (60 Hz)
Frequency range
From 47 Hz to 63 Hz
Total harmonic current distortion (THDi)
≤ 5%
Inrush current
≤ 10 x In
Input power factor
≤0.95
Output
Nominal DC Voltage
24 V / 48 V
Output DC voltage range
+/-15 %
Static regulation
+/-1 %
Voltage ripple
≤ 0.1 % RMS (disconnected battery)
Current limitation
I nominal
Charging mode
With valve regulated lead acid: single charge mode With recombination nickel cadminum: single charge mode (recommended) or dual charge mode
Charging current
With valve regulated lead acid: 0.05C10 to 0.1C With recombination nickel cadmium: 0.1C (up to 0.2C subject to battery enclosure certification limits)
IEC EN 60146-1-1:2009 IEC EN 61000-6-2:2006 IEC EN 61000-6-4:2007 AMD1:2011 IEC EN 61439-1:2011 IEC EN 60529:1989 AMD1:1999 NFC 58-311:1990 IEC EN 60079-0 IEC EN 60079-1 IEC EN 60079-7
Product information source: Chloride — official product page ↗. Specifications and documents belong to the manufacturer and may change; EDPN confirms the configuration for each project.