OVERVIEW

EDPN IBAD-2612-ED Intelligent Battery Charge & Discharge Unit.

The IBAD-2612-ED Intelligent Battery Activator & Discharger has 3 independent test methods: battery discharge, battery charge and battery cycle.

Focusing on lagging single cells, it can run a discharge test to estimate the real capacity, charge the battery intelligently, and run multiple discharge/charge cycles to activate a lagging battery. Test data can be uploaded to a PC, where the analysis software helps identify the quality problem of the cell.

FEATURES

Features & benefits.

Features

  • 1.2 V / 2 V / 6 V / 12 V charge & discharge: 1.2 V — 60 A discharge / 60 A charge; 2 V — 100 A / 100 A; 6 V — 30 A / 30 A; 12 V — 30 A / 30 A.
  • Multiple adjustable stop points to avoid excessive discharge and charge.
  • 7 inch touch LCD displays all real-time data and graphs with direct click operation.
  • Non-volatile internal memory saves several independent discharge & charge records without a laptop; review, delete or download to PC via USB.
  • PC analysis software: battery voltage curve, current curve, capacity histogram and data form; automatic EXCEL data report.

Protection

  • Input over-voltage — LCD prompt + sound warning
  • Reverse polarity — LCD prompt + sound warning
  • Overload — LCD prompt + sound warning
  • Overheat — LCD prompt + sound warning
SPECIFICATIONS

Technical data.

EDPN product data. Confirm the current datasheet and the project specification before selection.

Discharge & charge current ranges

0.9 – 1.8 VdcDischarge 0 – 60 A / Charge 0 – 60 A
1.7 – 2.4 VdcDischarge 0 – 100 A / Charge 0 – 100 A
5.1 – 15 VdcDischarge 0 – 30 A / Charge 0 – 30 A

Current measurement

Current range0 – 100 A
Accuracy & resolution≤ ±1 %, 0.1 A

Voltage measurement

Voltage range1.7 – 2.4 V
Accuracy & resolution≤ ±1 %, 0.01 V
Voltage range5.1 – 15 V
Accuracy & resolution≤ ±0.25 %, 0.1 V

Power supply

Power supply voltage220 VAC (-20 % to +30 %)
Frequency50 / 60 Hz
Power consumption350 W (max)

Communication & storage

Communication portUSB port
Internal memory4 GB Flash

CE certificate

LVD standardsEN 61010-1:2010, EN 61010-2-030
EMC standardsEN 61326-1:2013, EN 61000-3-2:2014, EN 61000-3-3:2013

Environment

Operating temperature0 to 45 °C
Storage temperature-10 to 60 °C
Humidity5 % – 95 % RH
Altitudebelow 2000 m
Working noise< 60 dB

Dimensions & weight

Main tester348 x 222 x 256 mm
Carrying case460 x 300 x 500 mm
Weight10 kg (main tester) / 20 kg (with accessories and case)
DOWNLOADS

Datasheets & documents.

EDPN datasheet

The datasheet for this EDPN product is available on request.

REQUEST DATASHEET →
MONITORING & ACCESSORIES

More models in this range.

ALL 2 MODELS →
LIFECYCLE SERVICES

Lifecycle services for this product.

ALL SERVICES →
CONTACT EDPN

New project or installed equipment?

Send the specification for a new project, or equipment details for service support.