EDPN SERVICES & SYSTEM · CRITICAL POWER SYSTEMS · VIETNAM
Chloride · Hazardous-Area Critical Power

XP90Z AC UPS ATEX/IECEx

Chloride® XP DC/AC UPS systems are tailor-made solutions designed to operate in the hazardous atmosphere.

UPS TypeAC UPS ATEX/IECEx
Ratingup to 80 kVA
TechnologySCR/IGBT
HAZARDOUS-AREA CRITICAL POWERCHLORIDE
XP90Z AC UPS ATEX/IECEx — manufacturer product image
MANUFACTURER PRODUCT IMAGESUPPLY · COMMISSIONING · SERVICE
OverviewFeaturesVideoSpecificationsDownloadsMore models
OVERVIEW

XP90Z AC UPS ATEX/IECEx.

APPLICATIONS
Offshore production process in Explosion-risk areasWellhead platforms / Unmanned platformsPipelines instrumentationRefineries
FEATURES

Features & benefits.

Key features

  • Small footprint To optimize space on offshore platform.
  • Durability Optimized thermal management.
  • Immunity Strong immunity to perturbations.
  • Safe control, door closed Allows the user to operate the switches, circuit breakers, and control buttons door closed.
  • Smart access to UPS data Large graphical user interface on the front.
  • Safe and easy maintenance Once open, the front door gives direct access to all components.
  • Alarms Embedded event logger (up to 2000 events). Close range Wi-Fi module - To download the event logger without opening the equipment enclosure.
VIDEO

Example of a Chloride explosion-proof UPS solution.

The video is loaded from YouTube (youtube-nocookie.com) only after you press play. Google may then receive your IP address and set cookies under its own policy — see our Cookie Policy.

SPECIFICATIONS

Technical data.

Summarised from the manufacturer’s published data. Confirm the current datasheet and the project specification before selection.

Input

AC Voltage3 x 400 V (380, 415)
Voltage tolerance+/- 10%
Frequency50 Hz (60 Hz)
Frequency tolerance+/- 5%

Output

AC Voltage1 x 230V (220, 240) 1 x 110V (115, 120) 3 x 400 V (380, 415)
Frequency50 Hz (60 Hz)
Overload inverter: 1 minute150 % of nominal power
Overload inverter: 10 minutes125 % of nominal power
Short circuit clearance: 1-ph output (in % of nominal current)250 %/100 ms - 175 %/5 s
Short circuit clearance: 3-ph output (in % of nominal current)315 %/100 ms - 220 %/5 s (Ph-N)
Power factor0.8 lagging
Allowable crest factor3/1

Battery

TypeValve Regulated Lead Acid (VRLA) Recombinaison Nickel Cadmium
AutonomyFrom few minutes to several hours, as per customer’s requirement
Battery current limitation (typical, float, mode)0.1 (Lead Acid or Nickel Cadmium battery)
Battery temperature compensation-3 mV / °C / cell

General Data

Relative humidity100% condensing
Operating altitude1000m max without derating
CoolingNatural

Enclosure

DesignATEX/IECex certified forZone1, II 2G Ex d IIB+H2 T3 (IEC 60079)
MaterialStainless steel (SS316L),Carbon steel (mild steel) or Aluminum
External ingress protectionIP 66 according to IEC 60529
DimensionsVarying according to ratings & options
DOWNLOADS

Datasheets & documents.

Product information source: Chloride — official product page ↗. Specifications and documents belong to the manufacturer and may change; EDPN confirms the configuration for each project.

HAZARDOUS-AREA AC UPS

More models in this range.

ALL 2 MODELS →
CONTACT EDPN

New project or installed equipment?

Send the specification for a new project, or equipment details for service support.